Positive Sequence Fault

Documentation Home Page ◇ ePHASORSIM Home Page
Pour la documentation en FRANÇAIS, utilisez l'outil de traduction de votre navigateur Chrome, Edge ou Safari. Voir un exemple.

Positive Sequence Fault

On this page:

Applying a fault to a bus causes it to act as an impedance was connected between it and a ground reference. The value of this impedance can be set using the G_fault and B_fault pins. Apply the fault by setting a non-zero value on the active3PGFault pin.

For line, the default value of the fault impedance is same as the bus fault; however, it cannot be changed. Apply the line fault by setting a non-zero value to faulty pin. The fault location in a line can also be provided using fault_distance_factor pin. By default this value is 0.5 which means a fault would happen right at the middle of the line.

Available I/O Pins 

No

Pin Description

Pin Type

Value/Unit

Instruction

No

Pin Description

Pin Type

Value/Unit

Instruction

1

Set/Get three-phase-to-ground fault status 

I/O

  • 1 Active

  • 0 Inactive

busID/active3PGFault

2

Set/Get fault conductance

I/O

pu

Default = 1e5 pu

busID/G_fault

3

Set/Get fault susceptance

I/O

pu

Default = 0 pu

busID/B_fault

4

Set/Get three-phase-to-ground fault

I/O

  • 1 Active

  • 0 Inactive

lineID/faulty

5

Set/Get distance for line fault from starting bus

I/O

0 < Value < 1

Default = 0.5

lineID/fault_distance_factor

Example

See row 11, 16 and 17 of Pins page in phasor01_IEEE39.xlsx file in ePHASORSIM example phasor01.