HIL2GO-310 - I/O Slot 2, Section B, P3 (CH 00-15) - Analog Outputs (OP48H10)
Connected I/O module is OP48H10 Fast I/O type H Module
Before designing cables, OPAL-RT recommends using the guideline Simulator EMC cable recommendations.
Before connecting the cables, make sure that the voltages or other electrical specifications are compatible with OPAL-RT DB37 specifications of I/O module OP48H10.
Connector P3 |
Do not connect to external power supply | |||
---|---|---|---|---|
DB37F Pin | Assignment | DB37F Pin | Assignment | |
1 | +AOUT00 | 20 | GND | |
2 | +AOUT01 | 21 | GND | |
3 | +AOUT02 | 22 | GND | |
4 | +AOUT03 | 23 | GND | |
5 | +AOUT04 | 24 | GND | |
6 | +AOUT05 | 25 | GND | |
7 | +AOUT06 | 26 | GND | |
8 | +AOUT07 | 27 | GND | |
9 | +AOUT08 | 28 | GND | |
10 | +AOUT09 | 29 | GND | |
11 | +AOUT10 | 30 | GND | |
12 | +AOUT11 | 31 | GND | |
13 | +AOUT12 | 32 | GND | |
14 | +AOUT13 | 33 | GND | |
15 | +AOUT14 | 34 | GND | |
16 | +AOUT15 | 35 | GND | |
17 | Reserved | 36 | GND | |
18 | Reserved | 37 | Reserved | |
19 | GND |
|
|
Analog output channels in this bitstream can be reserved by eHS and managed in the Schematic Editor.
DIGITAL OUTPUT BLOCK PARAMETERS | ||
Parameters | CH00-07 | CH08-15 |
Controller Name | 'OP4810 OpCtrl' | |
Data Out Port Number | 11 | 12 |
Number of channels | 8 | 8 |
Voltage Range | -10 V to +10 V | -10 V to +10 V |
OPAL-RT TECHNOLOGIES, Inc. | 1751, rue Richardson, bureau 1060 | Montréal, Québec Canada H3K 1G6 | opal-rt.com | +1 514-935-2323