HIL2GO-310 - I/O Slot 3, Section A and B (CH 00-05) - RS422 Digital Inputs/Outputs (OP5969)
The bitstream provided with the bundle HIL2GO-310 is configured for incremental rotary encoders with signals A, B and Z in input and output.
These signals are generated (output) and read (input) through the four DB9 connectors.
Section A - RS422 Digital Inputs
Connected I/O module is OP5969-1 RS422 Digital Inputs and Outputs (DIO)
Before designing cables, OPAL-RT recommends using the guideline Simulator EMC cable recommendations.
Before connecting the cables, make sure that the voltages or other electrical specifications are compatible with OPAL-RT DB37 specifications of I/O module OP5969-1.
Connector P1 | |||
DB9F pin (Channel) | Assignment | DB9F pin (Channel) | Assignment |
1 (CH00) | +ENC0 IN A | 6 (CH00) | -ENC0 IN A |
2 (CH01) | +ENC0 IN B | 7 (CH01) | -ENC0 IN B |
3 (CH02) | +ENC0 IN Z | 8 (CH02) | -ENC0 IN Z |
4 | Not used | 9 | Not used |
5 | Not used |
|
|
Connector P2 | |||
DB9F pin (Channel) | Assignment | DB9F pin (Channel) | Assignment |
1 (CH03) | +ENC1 IN A | 6 (CH03) | -ENC1 IN A |
2 (CH04) | +ENC1 IN B | 7 (CH04) | -ENC1 IN B |
3 (CH05) | +ENC1 IN Z | 8 (CH05) | -ENC1 IN Z |
4 | Not used | 9 | Not used |
5 | Not used |
|
|
Encoder In Parameters | Values |
Controller Name | 'OP4810XG OpCtrl' |
DataOut Port Number | 10 |
Number of Encoder Signals | 2 |
Section B - RS422 Digital Outputs
Connector P1 | |||
DB9F pin (Channel) | Assignment | DB9F pin (Channel) | Assignment |
1 (CH00) | +ENC0 OUT A | 6 (CH00) | -ENC0 OUT A |
2 (CH01) | +ENC0 OUT B | 7 (CH01) | -ENC0 OUT B |
3 (CH02) | +ENC0 OUT Z | 8 (CH02) | -ENC0 OUT Z |
4 | Not used | 9 | Not used |
5 | Not used |
|
|
Connector P2 | |||
DB9F pin (Channel) | Assignment | DB9F pin (Channel) | Assignment |
1 (CH03) | +ENC1 OUT A | 6 (CH03) | -ENC1 OUT A |
2 (CH04) | +ENC1 OUT B | 7 (CH04) | -ENC1 OUT B |
3 (CH05) | +ENC1 OUT Z | 8 (CH05) | -ENC1 OUT Z |
4 | Not used | 9 | Not used |
5 | Not used |
|
|
Encoder Out Parameters | Values |
Controller Name | 'OP4810XG OpCtrl' |