HYPERSIM Release Notes: 2019.3

Documentation Home Page HYPERSIM Home Page
Pour la documentation en FRANÇAIS, utilisez l'outil de traduction de votre navigateur Chrome, Edge ou Safari. Voir un exemple.

HYPERSIM Release Notes: 2019.3


HYPERSIM

Added

  • Added support for MATLAB R2019a and R2019b

  • Added a new PV component including a database from the California Energy Commission providing parameter values for 1000s of commercial cells

  • Added 6-phase FD line component

  • Added pin to access the auto-transformer tertiary for external impedance

  • Added several VSC components

    • 2-level converter (switching function)

    • 2-level converter (switching devices)

    • 3-level NPC converter (switching function)

    • 3-level NPC converter (switching devices)

    • Full-bridge converter (switching function)

    • Full-bridge converter (switching devices)

    • Boost converter (switching function)

  • Added "How to" example model for load flow

  • Added cyber-physical example model

  • Added Diagnostic panel in Target Manager to help fix target setup issues

  • Added GUI to edit UCM files

  • Added editable timeout in Simulation Settings/Advanced to manage simulation initialization and stopping sequences

  • Added capability to export data to CSV format in ScopeView

Improved

  • Improved workflow using snapshots

Fixed

  • Fixed issue with Testview when saving snapshots to file

  • Fixed need for administrative rights to launch the HYPERSIM installer

  • Fixed issue when importing an EDD file twice in the same design

  • Fixed issue with Squirrel Cage Induction Machine when connected directly to a converter

  • Fixed displayed angle unit to degree in load flow input data report

  • Fixed issue in ScopeView with Data Logger live acquisition where Play and Stop buttons were simultaneously enabled

I/O Interfaces

IEC 61850

  • Improved ICD file parsing when element names are duplicated

  • Fixed validation of uniqueness of GOOSE messages done using the MAC address in combination with the AppID

TCP-UDP

  • Added support for OPAL-RTLinux 64-bit

  • Added support for configuration via GUI

FPGA-Based Simulation

  • Added support of PMSM Variable DQ machine

  • Added support of SCIM machine

  • Added support of DFIM machine

  • Added support for new form factor eHSx16

  • Improved bitstream selection workflow

  • Fixed issue using eHS on OPAL-RTLinux 64-bit

Communication Network Simulation

  • Improved installation workflow by automating the configuration of virtual interfaces upon installing HYPERSIM