Documentation Home Page ◇ HYPERSIM Home Page
Pour la documentation en FRANÇAIS, utilisez l'outil de traduction de votre navigateur Chrome, Edge ou Safari. Voir un exemple.
HYPERSIM Release Notes: 2021.1
HYPERSIM
Added
Added exciter library model:
Added governor library model:
Added example models :
Added support for Python version 3.7
Added the following Python API commands:
getAllDevicesNames
renameSignal
addPinsToDevice
createSubCircuit
ScopeView.setDataSourceParameter
Added subcircuit support in the following Python API commands:
addDevice
includeDevice
removeDevice
renameDevice
connectDevices
Added Signal Routing library models allowing sending/receiving signals through all levels of subcircuits or pages without the need for drawn wires
Radiolink emitter
Radiolink receiver
Added Multi-Breaker and CmdLine commands in TestView
Added error message to prevent users from opening more than one instance of HYPERSIM
Added option to "solve control inputs before solving power" advanced option in simulation settings. It remains unchecked for existing examples but is activated by default with newly created models.
Added support for EXST1 and ST1A in PSS®E import
Added carrier frequency input and dead time parameter in PWM average generators for 2-Level Converter and Full-Bridge Converter
Improved
Improved I/O assignment and sensor management workflow
Fixed
Fixed issue where some signals in a bundle would be renamed during EDD import, potentially leading to wrong signal connections on the same observable
Fixed issue where some signal names could conflict during EDD import, potentially leading to import interruption by a popup
Fixed the output behavior of H(s) component at the beginning of the simulation when a non-zero constant is connected to the "init" input or a zero constant is applied at input "u"
Fixed DC Circuit Breaker form default values to avoid solver divergence in some cases
Fixed Task Manager's SaveConfig option wrongly opening OpenConfig menu
Fixed issues with scripts generated using a template in the Sequence Manager where paths include space characters
Fixed issues with EDD import when models containing UCMs have their .def file located next to the .edd file
Fixed Control Exciter library models:
AC2A: Fixed the initialization of VA0 and the non-windup integrator producing the VE signal
EXAC3: Fixed Efd output at the initialization of the feedback loop signal when EFDN > Efd0
EXST1: Fixed various issues with In1, Vt and Vc1 pins and the lower limit of the exciter
Fixed Autotransformer displayed base winding voltages in rmsLL
Fixed Voltage Source base voltage value in EDD export
Fixed several components that were not reported under the correct category in the Netlist
UI: Fixed issue where some connections wouldn't show on the design when connecting multiple pins to the same bundle
UI: Fixed default signal names being cleared when doing Paste Special with "keep old names"
UI: Fixed new default names occasionally assigned to devices on Paste Special even if "keep names" specified
Removed
Removed protection example model:
Distance 21 POTT.
I/O Interfaces
General
Improved network configuration through harmonization of parameters across relevant interfaces (C37.118, DNP3, IEC 60870-5-104, Modbus) and implementation of automatic IP aliasing generation
C37.118 Slave
Fixed driver behavior when multiple points connected to the same sensor
DNP3
Added support for double bit binary input
Added support for integrity polling (new read mode)
Added support to run the driver on Windows
IEC 60870-5-104
Fixed display issue in point lists of the configuration menu
IEC 61850
Fixed model loading and resetting issues coming from an incompatibility between IEC 61850 and Modbus RTU (Master and Slave)
Modbus Slave/Master
Fixed initialization failures due to synchronization issues
OPAL-RT Board
Added support for OP5369 digital card
Synchronization
Added automatic discovery of the network interface name
FPGA-Based Simulation
Added support for user-defined time step configuration
Added generation of eHS compilation logs
Added support of OP4510 Kintex-7 410T based firmware
Added support for QE on RS422
Added support for configuring more than 32 AO channels
Improved the names of machine input and output signals
Fixed issues with configurations using more than 2 SCIM/DFIM/SM
Fixed the output amplitude of DQ voltage of the SCIM/DFIM/SM being dependent on time step
Communication Network Simulation
Improved user workflow (DRV-3736)
OPAL-RT TECHNOLOGIES, Inc. | 1751, rue Richardson, bureau 1060 | Montréal, Québec Canada H3K 1G6 | opal-rt.com | +1 514-935-2323