Documentation Home Page ◇ HYPERSIM Home Page
Pour la documentation en FRANÇAIS, utilisez l'outil de traduction de votre navigateur Chrome, Edge ou Safari. Voir un exemple.
HYPERSIM Release Notes: 2021.3
HYPERSIM
Added
- Added the possibility of having negative initial flux in 2-Winding 1-Phase Saturable Transformer
- Added the following Python API | Commands:
- recheckPorts
- setDeviceFillColor
- setDeviceLineColor
- setSignalLineColor
- setSignalLineWidth
- setProperty
- option name in the addDevice command
- Added output integrator (1/sTe) to have non-windup limits on AC8B exciter library model
- Added support for OP4510 in FPGA-Based PMSM Drive Transportation example model
- Added the possibility in the Task Manager view to copy lines of the "prodID" column to the "set procID" column
- Added diode in PV Array model to remove operating temperature limitation
- Added capability to bulk edit the execution time estimate of multiple tasks in Task Manager
- Added Warning message when clicking on Clear sensor
Improved
- Improved the Signal Monitoring component by allowing it to be displayed as an LED
- Improved value accuracy displayed by the Signal Monitoring block:
- Improved error message when the target license expires
Fixed
- Fixed phase A voltage mismatch when switching between balanced and unbalanced modes in voltage source
- Fixed I/O factor column not showing when selecting "I/O" view in sensor summary
- Fixed issue when setting to 0 the lower limit of the PID integral integrator of AC8B exciter model during a voltage reference decrement test
- Fixed unapplied limitation on number of taps (50) in transformers
- Fixed DNP3 Slave configuration in DNP3_MASTER_SLAVE example model
- Fixed issue with Python API setCommandParameter when the parameter is of type String
- Fixed wrong user feedback indicating clearing of previous load flow information when clicking on Set Initial Conditions
- Fixed crash when putting wrong number in I/O connection column of sensor menu
- Fixed pu option not available in forms of Switches and Breakers components
- Fixed display issue where some menus show a white page when using remote desktop connection
Removed
- Removed internal ground in the PV Array model
I/O Interfaces
General
- Improved view for OPAL-RT Board and C37.118 master I/O interfaces
- Fixed driver setup and cleanup commands not properly being registered when using multiple models during the same HYPERSIM session
OPAL-RT Board
- Added support for OP5330 analog out cards with configurable sampling rates
- Added support for the OP5143 Artix-7 board enabling I/O expansion through fiber optics on the OP5033XG platform
- Added debugging feature to log register accesses during simulation load
- Fixed isolation losses on OPAL-RTLinux 3 (x64-based platform)
FPGA-Based Simulation
A more detailed list of release notes is available at C:\OPAL-RT\eFPGASIM\v2.8.2\Docs\ReleaseNotes
- Added initial (beta) release of eHS Gen5 core, enabling faster simulation and PWM frequency resolution up to 250 kHz
- Added support for up to 8 Time-Stamped Bridge (TSB) in eHS Gen5 (EFS-4571, EFS-4560)
- Added new OP4510 firmware with support for 2 machines and the following I/O configuration: OP5369, OP5330-3, OP5342 and OP5330-3 (EFS-4367)
- Added support for Roff in Gen 4 Half-Bridge parser to improve stability (EFS-4386)
- Added error for exceeding the maximum number of supported AC sources (EFSTT-1103)
- Improved eHS and machine drivers to enhance the numerical stability of simulations
- Fixed FPGA reset issue with Generic machine model (EFS-3999)
- Fixed eHS circuit loading failure while modifying circuit without closing the FPGA-based circuit component form between attempts (EFSTT-1104)
- Fixed issue with Sources having the same name (in Schematic editor subsystems) appearing as a single interface port (EFSTT-1095)
Communication Network Simulation
- Added a new I/O interface to facilitate configuration of EXata CPS on OPAL-RTLinux 3 (x64-based platform)
OPAL-RT TECHNOLOGIES, Inc. | 1751, rue Richardson, bureau 1060 | Montréal, Québec Canada H3K 1G6 | opal-rt.com | +1 514-935-2323