HYPERSIM Release Notes: 2020.3
Documentation Home Page ◇ HYPERSIM Home Page
Pour la documentation en FRANÇAIS, utilisez l'outil de traduction de votre navigateur Chrome, Edge ou Safari. Voir un exemple.
HYPERSIM Release Notes: 2020.3
HYPERSIM
Added
- Added user guide to help EMTP users go to real-time with HYPERSIM
- Added Sequence Manager tool to record and manage test sequences from manual manipulations
- Added support for wound rotor in recently added Asynchronous Machine [The former induction machine models will be kept as Legacy]
- Added support for MATLAB R2020a and R2020b
- Added exciter library models:
- IEEET2
- IEEET3
- IEEEVC
- EXDC2
- EXST1
- EXST3
- EXPIC1
- SCRX
- Added governor library model:
- WEHGOV
- Added stabilizer library model:
- PSS2A
- Added example models :
- Added a Data Name filter in the Sensor configuration view to help accelerate I/O assignment
- Added options to rename and delete I/O Interfaces
- Added Sigcmp to Advanced Function Editor in ScopeView, allowing comparison of a test signal to a reference signal with a user-defined tolerance
- Added Time format option in the data logger file browsing with ScopeView, allowing easily shifting results to time = 0 in graphs
- Added support for EXAC3, IEEET1, HYGOV, SCRX, AC8B, PSS2A and WEHGOV in PSS®E import
- Added progress bar when importing PSS®E files
- Added progress bar on Apply/Ok of I/O interface modifications to better follow updates of large I/O configurations
- Added Python API function to rename devices
Improved
- Improved Python API command setComponentParameter, making it synchronous, thus removing the need to add wait time after its call
- Improved PSS®E import to skip buses with IDE=4 and all components connected to them
- Improved PSS®E import to manage multiple sources (machines or voltage sources) on the same bus; the biggest source (the one with highest PT value in PSS®E) stays as is, whereas the smaller ones are connected through an intermediary resistor and their type is changed to PQ
Fixed
- Fixed inconsistencies in tooltips of Network component forms
- Fixed unit of winding voltages for Saturable 2-winding transformer with tap changer that wasn't set to rmsLL like other transformers in the previous version
- Fixed issue where HYPERSIM would not start properly on a completely new Windows installation because of missing Microsoft libraries
- Fixed various issues with In1, Vt and Vc1 pins and the lower limit of exciter ST1A
- Fixed issue in AC3A exciter form where diagram would show Voel
- Fixed voltage source base voltage display value
- Fixed issue where sensor changes could be detected even if no changes were executed
- Fixed issue during uninstallation where some documentation files would remain
- Fixed occasional crash of a model engine when opening the Netlist after a specific sequence of actions
Removed
- Removed automatic generation of the EXata CPS files when opening I/O Interface
I/O Interfaces
C37.118 Slave
- Fixed issue when sensors of a given slave are dispatched on different cores
- Fixed missing editable slave name in I/O Interface configuration
DNP3
- Fixed possible crash of asynchronous process with certain configurations
IEC 61850
- Fixed UI crash when .icd file parsing failed
Modbus Slave
- Fixed issue with initial values and float data types
- Improved automatic setting of ID for TCP slaves
OPAL-RT Board
Fixed issue where the FPGA bitstream could be reprogrammed twice upon starting the simulation
OPC UA Server
- Fixed Advanced Options which where showing at the root of the I/O Interface instance rather than in other elements of the tree
FPGA-Based Simulation
Added support of release notes in firmware description
Added 1st order low pass filter on PMSM VDQ PQ measurements
- Added support of native SFP link on all firmware to allow multi-FPGA configuration
Fixed format of angle of PMSM VDQ FPGA module
Fixed issue on second machine of Dual PMSM Motor Vdq with park transform, rotor offset and initial angle parameters
, multiple selections available,