Documentation Home Page ◇ Hardware Home Page
Pour la documentation en FRANÇAIS, utilisez l'outil de traduction de votre navigateur Chrome, Edge ou Safari. Voir un exemple.
OP5354 DB37F Pin Assignment
The following tables provide the general pin assignments for the OP5354 DB37 connectors.
Legacy product : we no longer sell this product. The recommended replacement card is the OP5360. Contact your local representative for details.
Detailed pin assignments for all connectors can be found in the System Description document provided with your order, or refer to the general pin assignment of your specific unit.
Before designing cables, OPAL-RT recommends using the guideline Simulator EMC cable recommendations.
Group A and B - Connector P1 - Channel 00 to 15 | OP5354 DB37F Pin Assignment
| Group A and B - P2 Connector - Channel 16 to 31 | ||||||
---|---|---|---|---|---|---|---|---|
DB37F Pin | Assignment | DB37F Pin | Assignment | DB37F Pin | Assignment | DB37F Pin | Assignment | |
1 | +DOUT00 | 20 | GND_ISO1** | 1 | +DOUT16 | 20 | GND_ISO2 | |
2 | +DOUT01 | 21 | GND_ISO1 | 2 | +DOUT17 | 21 | GND_ISO2 | |
3 | +DOUT02 | 22 | GND_ISO1 | 3 | +DOUT18 | 22 | GND_ISO2 | |
4 | +DOUT03 | 23 | GND_ISO1 | 4 | +DOUT19 | 23 | GND_ISO2 | |
5 | +DOUT04 | 24 | GND_ISO1 | 5 | +DOUT20 | 24 | GND_ISO2 | |
6 | +DOUT05 | 25 | GND_ISO1 | 6 | +DOUT21 | 25 | GND_ISO2 | |
7 | +DOUT06 | 26 | GND_ISO1 | 7 | +DOUT22 | 26 | GND_ISO2 | |
8 | +DOUT07 | 27 | GND_ISO1 | 8 | +DOUT23 | 27 | GND_ISO2 | |
9 | +DOUT08 | 28 | GND_ISO1 | 9 | +DOUT24 | 28 | GND_ISO2 | |
10 | +DOUT09 | 29 | GND_ISO1 | 10 | +DOUT25 | 29 | GND_ISO2 | |
11 | +DOUT10 | 30 | GND_ISO1 | 11 | +DOUT26 | 30 | GND_ISO2 | |
12 | +DOUT11 | 31 | GND_ISO1 | 12 | +DOUT27 | 31 | GND_ISO2 | |
13 | +DOUT12 | 32 | GND_ISO1 | 13 | +DOUT28 | 32 | GND_ISO2 | |
14 | +DOUT13 | 33 | GND_ISO1 | 14 | +DOUT29 | 33 | GND_ISO2 | |
15 | +DOUT14 | 34 | GND_ISO1 | 15 | +DOUT30 | 34 | GND_ISO2 | |
16 | +DOUT15 | 35 | GND_ISO1 | 16 | +DOUT31 | 35 | GND_ISO2 | |
17 | Refer to unit’s pin assignment* | 36 | Refer to unit’s pin assignment* | 17 | Refer to unit’s pin assignment* | 36 | Refer to unit’s pin assignment* | |
18 | Vuser 1 | 37 | GND_ISO1 | 18 | Vuser 2 | 37 | GND_ISO2 | |
19 | Refer to unit’s pin assignment* |
|
| 19 | Refer to unit’s pin assignment* |
|
|
* Unit can be a Real-time Simulator or an FPGA Processor and IO Expansion Unit from the OP4000 or the OP5000 series.
** GND_ISO: Isolated ground
OPAL-RT TECHNOLOGIES, Inc. | 1751, rue Richardson, bureau 1060 | Montréal, Québec Canada H3K 1G6 | opal-rt.com | +1 514-935-2323
Follow OPAL-RT: LinkedIn | Facebook | YouTube | X/Twitter