OpOutput

Page Content

Library

rtlab

Block

The OpOutput block allows the user to interconnect the model and an I/O.

OpOutput block

Mask

OpOutput mask.

Description

This block allows the user to create a connection interface between the model and an entity like an I/O.

Parameters

Identifier

Allows the user to specify a name for the connection interface. Default is OpOutput. All identifiers must be unique.

Number of parent blocs in identifier

Includes the parent blocks names in the identifier in order to make it unique.

Inputs

Data

the data sent to the entity connected to the block.

Outputs

This block has no outputs.

Characteristics and Limitations

The signal dimension of an OpOutput block is limited by the SIGNAL_VECTOR_SIZE_LIMIT variable.

Signal(s) with more than 1000 values will be disabled. Use SIGNALS_VECTOR_SIZE_LIMIT environment variable to modify this limit.

Direct Feedthrough

No

Discrete sample time

Yes

XHP support

Yes