Documentation Home Page ◇ RT-LAB Home Page
Pour la documentation en FRANÇAIS, utilisez l'outil de traduction de votre navigateur Chrome, Edge ou Safari. Voir un exemple.
OpAsyncRecv
Library
rtlab/Communication/Asynchronous
Block
The OpAsyncRecv block allows a user to receive data from the asynchronous process started by the associated controller.
Mask
Description
The OpAsyncRecv block is used to receive data from the application started by the associated controller. This block simply reads data from the shared memory. After that, the data are available in the model. If a new value is not available, the OpAsync_Recv gives the latest value placed into the shared memory. Refer to the section RT-LAB Asynchronous process of chapter RT-LAB Connectivity of the User Guide for more details.
Parameters
Controller ID | Specifies the controller ID that the OpAsync_Recv block will use. |
---|---|
Receive ID | Specifies the ID of this OpAsync_Recv block. This ID is used as an identifier by the asynchronous program. |
Display parameters list | Masks or Unmasks the parameters described below. |
Float parameter 1 .. 5 | Any value entered in this field is available in the asynchronous application by calling the OpalGetAsyncRecvParameters function. These five values are placed in the FloatParam array in the Opal_RecvAsyncParam structure. EX: |
String parameter 1 .. 5 | Any characters entered in this field are available in the asynchronous application by calling the OpalGetAsyncRecvParameters function. This five string are placed in the StringParam array in the Opal_RecvAsyncParam structure. EX: Opal_RecvAsyncParam Param; |
Inputs
Timeout | A possible timeout value to be used by the asynchronous program via a call to function OpalGetAsyncRecvIconTimeout. |
---|
Outputs
Error | Outputs error values which can be set by the user's asynchronous program via the OpalSetAsyncSendIconError function. |
---|---|
Status | The user's asynchronous program uses this output to indicate the status of the reception (OpalSetAsyncRecvIconStatus). |
Data | The data line contains the values placed into the shared memory by the asynchronous program. It is possible to use a demux block to separate multiple received values. |
Characteristics and Limitations
Direct Feedthrough | N/A |
---|---|
Discrete sample time | No |
XHP support | Yes (Partial XHP only) |
Work offline | No |
OPAL-RT TECHNOLOGIES, Inc. | 1751, rue Richardson, bureau 1060 | Montréal, Québec Canada H3K 1G6 | opal-rt.com | +1 514-935-2323