Documentation Home Page ◇ RT-LAB Home Page
Pour la documentation en FRANÇAIS, utilisez l'outil de traduction de votre navigateur Chrome, Edge ou Safari. Voir un exemple.
OpMonitoringStop
Library
rtlab/Monitoring
Block
The OpMonitoringStop block enables you to monitor certain parts of a model.
Mask
Description
The OpMonitoringStart block enables you to monitor certain parts of a model. This block must be used with an OpMonitoringStop block The following figures show how to insert the block inside a subsystem.
An atomic subsystem must be placed between the two blocks to force Simulink to compute all the blocks inside this subsystem before outputting the values. Then atomic subsystem and monitoring block must be grouped inside an atomic subsystem to ensure the order of these blocks remains unchanged (i.e. OpMonitoringStart must call before OpMonitoringStop during a computation step).
Parameters
User Name | This field contains the name of the event to be registered. The same event name must be used in the corresponding OpMonitoringStart block. |
---|
Inputs
The inport must be connected to an atomic subsystem. The input's value could not be used inside the model, the connection is only used to force the order block by the Simulink scheduler.
Outputs
This block has no outputs.
Characteristics and Limitations
This block has no special characteristics.
Direct Feedthrough | No |
---|---|
Discrete sample time | Yes |
XHP support | Yes |
Work offline | No |
OPAL-RT TECHNOLOGIES, Inc. | 1751, rue Richardson, bureau 1060 | Montréal, Québec Canada H3K 1G6 | opal-rt.com | +1 514-935-2323