OpInput

Page Content

Library

rtlab

Block

The OpInput block allows the user to interconnect the model and an I/O.

Figure 1: OpInput block

Mask

Figure 2: OpInput mask

Description

This block allows the user to create a connection interface between the model and an entity like an I/O.

Parameters

Identifier

Allows the user to specify a name for the connection interface. Default is OpInput. All identifiers must be unique.

Number of parent blocs in identifier

Includes the parent blocks names in the identifier in order to make it unique.

Default Value

Sets a value to be output by the block in case no I/O is connected.

Default Values Type

Used to specify the data type used by the default value.

Inputs

This block has no inputs.

Outputs

Data

the data received from the entity connected to the block.

Characteristics and Limitations

The signal dimensions for an OpInput block is limited by the minimum between PARAM_VECTOR_SIZE_LIMIT and SIGNAL_VECTOR_SIZE_LIMIT variables.

Parameter(s) with more than 1000 values will be disabled. Use PARAM_VECTOR_SIZE_LIMIT environment variable to modify this limit.

Signal(s) with more than 1000 values will be disabled. Use SIGNALS_VECTOR_SIZE_LIMIT environment variable to modify this limit.

Direct Feedthrough

No

Discrete sample time

Yes

XHP support

Yes

Work offline

Yes