PI Section, 1-ph
Description
The PI line model is mainly used for short transmission lines. The equivalent circuit is shown below.
It is assumed that the capacitance on both sides are identical.
Mask and Parameters
General Parameters
Name | Description | Unit | Variable = {Possible Values} | |||
---|---|---|---|---|---|---|
Description | Use this field to add information about the component | Description = {'string'} | ||||
Line Length | The length of the line | km | length = {0, 1e64} | |||
Base power (perPhase) | Base value for PU conversion | MVA per phase | pBase = { [1, 1e64] } | |||
Base voltage (rmsLN) | Base value for PU conversion | kV rms LN | vBase = { [1, 1e64] } | |||
Base frequecy | Base value for PU conversion | Hz | fBase = { [1, 1e64] } |
Impedances Parameters
Name | Description | Unit | Variable = {Possible Values} | |||
---|---|---|---|---|---|---|
Resistance - R | Resistance of the RL branch | Ω/km | R = {'-1e64, 1e64'} | |||
Inductance - L | Inductance of the RL branch | H/km | L = {'-1e64, 1e64'} | |||
Capacitance - C | Capacitance equivalent to twice the shunt capacitor value | F/km | C = {'-1e64, 1e64'} |
Keep one line to create space with the next section
Ports, Inputs, Outputs and Signals Available for Monitoring
Ports
This component has two 1-phase terminals:
Name | Description |
---|---|
net_1 | Network connection of the left (+) side |
net_2 | Network connection of the right side |
Inputs
None
Outputs
None
Sensors
At acquisition, the signals available by the sensors are:
Name | Description | Unit |
---|---|---|
I1 | Current flowing into port net_1 | A |
I2 | Current flowing out of port net_2 | A |