Added

  • Added support for MATLAB R2023a
  • Added support for multiple Dashboards when having several HYPERSIM instances or models opened at the same time. See OPAL-RT Dashboards
  • Added How To Example Model:
  • Added the following Python API commands:
    • the simulation mode option in the setTarget command
  • Added PSSe Import Option
    • Added Group Machines With Controls option by default
  • Added a notification in case of a simulation crash (limitation: feature not available on Red Hat 32-bit OS)
  • Added Python 3.9 and 3.10 compatibility for DataLogger API modules
  • Added Processor Performance information to the .simout
  • Added ScopeView template in the FPGA scope example model

Improved

  • Improved Impedance Measurement workflow
  • Improved logging in the console with timing
  • Improved message when requesting a license without network connection
  • Improved missing license key not found error message
  • Improved error message when 2 control output pins feed the same signal
  • Improved validation of the topology
  • Improved time to build the topology

Fixed

  • Fixed Target I/O Interface component not renaming pins containing certain forbidden characters on the schematic

  • Fixed issue with Target I/O Interface component when a data point is lost
  • Fixed simulation still running on the target in case of an engine crash on the host (limitation: fix not available on Red Hat 32-bit OS)
  • Fixed sh: /sbin/lspci: No such file or directory error in the target diagnostic for OPAL-RTLinux OS
  • Fixed eHS target license missing error
  • Fixed HYPERSIM average simulation time value in .simout file
  • Fixed HYPERSIM RTMonitor CPU "No Selected CPUs" error

Removed

  • Removed HyperView Monitor tab
  • Removed HyperView Line tab and moved it to corresponding Lines component masks
  • Removed HyperView SyncMac tab and moved it to corresponding Synchronous machine with fault component mask
  • Removed Sequence Manager for this version due to instabilities. It will be back in the next version

I/O Interfaces

C37.118 Slave

Improved

  • Improved C37.118 example model with automatic synchronization interface detection

Fixed

  • Fixed issue with the process not being migrated to the correct CPU core
  • Fixed loss of connection issue with long simulations


OPAL-RT Board

Improved

  • Added a pop-up to warn users that OP4200 support as MuSE remote target will no longer be supported as of HYPERSIM 2024.2

Fixed

  • Fixed switching to a 64 port loadin/loadout bitstream not showing the correct configuration menu until the I/O Interface menu is restarted
  • Fixed flashupdate unable to load dynamic libraries
  • Fixed standard repository not finding default bistreams

OPC-UA Server

Fixed

  • Fixed issue with the TCP server not attaching to the configured interface
  • Fixed publish paths and allowed multiple datapoint names in different subfolders

Synchronization

Added

  • Added possibility to apply an offset to the received timestamp before returning it to the model

TCP-UDP

Fixed

  • Fixed issue with float and double-bit precision data types

FPGA-Based Simulation

Added

  • Added support for the PMSM VDQ machine in eHS Gen5 VC707 firmware
  • Added licensing management for eHS Gen5 and PADE5 discretization method
  • Added new Induction Machine with Saturation model
  • Added support for single switches in eHS Gen5 firmware
  • Added capability to use User Defined Back EMF profile for PMSM and BLDC

Improved

  • Improved reset logic of eHS to fix initial state at model startup
  • Improved names of I/O connections to match Hardware Slot and Channel identification
  • Improved Installer/Uninstaller performance
  • Improved error message for malformed JSON resource file returning "Error (139)"

Fixed

  • Fixed issue when connecting a measurement to multiple AO from different mezzanines
  • Fixed issue when disconnecting some, but not all, gate connections from multi-level switching components (Half Bridge, Three-Level, Cycloconverter)
  • Fixed Thyristor behavior in eHS Gen4
  • Fixed issue preventing setting of rectangular Ldq matrices in PMSM VdQ
  • Fixed PMSM Variable DQ parameter file that may contain different numbers of values along the direct and the quadrature axes

A more detailed list of release notes is available at C:\OPAL-RT\eFPGASIM\v2.13.2.61\Docs\ReleaseNotes\Releases_Notes.pdf


OPAL-RT TECHNOLOGIES, Inc. | 1751, rue Richardson, bureau 1060 | Montréal, Québec Canada H3K 1G6 | opal-rt.com | +1 514-935-2323