Modbus Slave | Configuration
Accessing the I/O Interface Configuration
The Modbus slave communication protocol can be configured through the I/O Interface Configuration tool available from the HYPERSIM ribbon.
For more information on the general use of the I/O Interface Configuration, see I/O Interface Configuration.
General Configuration
Use an RT core for asynchronous computation |
|
Enable verbose mode | If enabled, additional information is displayed in the HYPERSIM log during the loading of the model. |
Enable virtual mode | In virtual mode, the model can be executed even if this I/O interface is not compatible with the hardware configuration of the system. The connections between the model and the I/O interface will be done during the initialization, but the I/O interface will not do anything. The virtual mode can be used to troubleshoot problems on a system without having the required hardware, or to prepare a model with different I/O interfaces even if the final hardware platform is not available. |
Slave Configuration
General Parameters
Mode | Select TCP or RTU. |
Slave ID | ID of the Modbus slave. Each slave must be configured with a unique identification number. This is due to the fact that:
|
Cycle output rate (ms) | Defines the rate (in milliseconds) at which the data from the model is written in the slave's outputs (coils and holding registers). When the slave's outputs are controlled both from the model and from the master, this parameter must be set to a value greater than the time step of the model. Otherwise, the write operations made by the master are never reflected in the model. |
Byte ordering | Defines how 32-bit data is encoded. Any of the byte ordering cases are possible (ABCD, BADC, CDAB, DCBA). ABCD refers to the network byte order. |
Permit read/write requests with address gaps | From the lowest address to the highest address configured, this option creates dynamically new coils, discrete inputs, holding registers and input registers at every address that is not defined by the user and assigns a value of 0. |
TCP Specific Parameters
NIC name | The desired network interface name. The proper interface name should be selected based on the information given by the Linux command "ifconfig". If a Modbus master is running on the same machine as the Modbus slave, the loopback network interface must be used ('lo'). If the driver is running on Windows this field will be ignored. |
IP address | The IP address of the Modbus slave. If a Modbus master is running on the same machine as the Modbus slave, the loopback IP address must be used (127.0.0.1). |
TCP port | Select the TCP port on which the slave will wait for a connection. |
RTU Specific Parameters
Serial port | Path to the serial interface to be used. The default serial interface name of the first port on a SuperMicro motherboard (OPAL-RT chassis) is "/dev/ttyS0". |
Serial baudrate | Speed at which Modbus RTU slave is configured to communicate. |
Serial data bits | Number of data bits the Modbus RTU slave is configured to communicate. |
Stop bits | Number of stop bits the Modbus RTU slave is configured to communicate. |
Serial parity | Parity at which the Modbus RTU slave is configured to communicate. |
For each slave instance, the inputs and outputs must be configured. The slave will reply to the master requests continuously as fast as possible.
Coils
Name | A specific name to recognize the coil. | |
Address | The address at which the slave holds that coil. | |
Initial value | If the coil is only controlled by the master, it will take this value (as a binary number) at the beginning of the simulation. Otherwise, the initial value comes from the model. | |
Control from | Master | The coil is a model input and can only be changed by a Modbus master. |
Model | The coil is a model output and can only be changed by the model. A Modbus master can read this coil and if it writes a value to it, it is overwritten automatically by the model. | |
Both | The coil is directly connected to the model input and a "from model" data point is instantiated. This one overwrites the coil value at the interval specified by the cycle output rate (ms) parameter. |
Discrete Inputs
Name | A specific name to recognize the discrete input. |
Address | The address at which the slave holds that discrete input. |
Holding Registers
Name | A specific name to recognize the holding register. | |
Address | The address at which the slave holds that holding register. | |
Initial value | If the holding register is only controlled by the master, it takes this value at the beginning of the simulation. Otherwise, the initial value comes from the model. | |
Control from | Master | The holding register is a model input and can only be changed by a Modbus master. |
Model | The holding register is a model output and can only be changed by the model. A Modbus master can read this holding register and if it writes a value to it, it is overwritten automatically by the model. | |
Both | The holding register is directly connected to the model input and a "from model" data point is instantiated. This one will overwrite the holding register value at the interval specified by the cycle output rate (ms) parameter. | |
Register type | UINT16 | This is the standard format of Modbus slave holding registers. |
INT16 | This is a non standard format of Modbus slave holding registers. The support for this type is added to improve usability. | |
UINT32 | This is a non standard format of Modbus slave holding registers. The support for this type is added to improve usability. The driver supports multiple byte orderings as described above in the slave configuration. A UINT32 holding register will take two UINT16 registers. This means that there should be an offset of 2 after each UINT32 holding register, otherwise the driver initialization will fail. | |
INT32 | This is a non standard format of Modbus slave holding registers. The support for this type is added to improve usability. The driver supports multiple byte orderings as described above in the slave configuration. An INT32 holding register will take two UINT16 registers. This means that there should be an offset of 2 after each INT32 holding register, otherwise the driver initialization will fail. | |
FLOAT32 | This type is based on the single-precision floating-point IEEE 754 standard (32 bits). The Modbus slave driver supports multiple byte orderings as described above in the slave configuration. A FLOAT32 holding register will take two UINT16 registers. This means that there should be an offset of 2 after each FLOAT32 holding register, otherwise the driver initialization will fail. |
Input Registers
Name | A specific name to recognize the input register. | |
Address | The address at which the slave holds that input register. | |
Register type | UINT16 | This is the standard format of Modbus slave input registers. |
INT16 | This is a non standard format of Modbus slave input registers. The support for this type is added to improve usability. | |
UINT32 | This is a non standard format of Modbus slave input registers. The support for this type is added to improve usability. The driver supports multiple byte orderings as described above in the slave configuration. A UINT32 input register will take two UINT16 registers. This means that there should be an offset of 2 after each UINT32 input register, otherwise the driver initialization will fail. | |
INT32 | This is a non standard format of Modbus slave input registers. The support for this type is added to improve usability. The driver supports multiple byte orderings as described above in the slave configuration. An INT32 input register will take two UINT16 registers. This means that there should be an offset of 2 after each INT32 input register, otherwise the driver initialization will fail. | |
FLOAT32 | This type is based on the single-precision floating-point IEEE 754 standard. The Modbus slave driver supports multiple byte orderings as described above in the slave configuration. A FLOAT32 input register takes two UINT16 registers. This means that there should be an offset of 2 after each FLOAT32 input register, otherwise the driver initialization will fail. |