Description

This block processes the communication and configuration between the RT-LAB CPU-based model and the FPGA-based Electrical Machine model. It supports up to 4 machines, and each of them can be one of the following machine types:

  • Synchronous Machine with Round Rotor

  • Synchronous Machine with Salient-pole Rotor

  • Induction Machine with Squirrel-cage Rotor

  • Induction Machine with Double Squirrel-cage Rotor

  • Doubly-fed (Wound Rotor) Induction Machine

  • Permanent Magnet Synchronous Machine

  • Brushless DC motors

The Synchronous Machine model is presented in Synchronous Machine Model page.

The Induction Machine model is presented in Induction Machine Model page.

The Permanent Magnet Synchronous Machine model is presented in Permanent Magnet Synchronous Machine Model page.

The Brushless DC Machine Machine model is presented in Brushless DC Machine Model page.


Mask Parameters

General TAB

Block mode: This parameter is used to select which type of FPGA-based machine model that is available in the firmware. It supports:

  • Quad generic machine model mode for simulation of up to 4 Synchronous Machine or Asynchronous machine models.

  • Dual PMSM Variable DQ mode for simulation of up to 2 Permanent Magnet Synchronous Machine or Brushless DC motor models.

 

Once the selection is made, the available model types will be refreshed in each machine tab. This parameter is global to the block. For simulating of a Induction machine and a Permanent magnet machine in the same CPU model, it will be require to use two seperate Generic Machines CPU block, one configured with the generic machine model option and the second configured with the PMSM option.

Number of Machines: In the General tab, the number of machines (up to 4 for Generic Machine mode, up to 2 for PMSM modes) can be selected.

Solver Time Step [Ts(sec)]: Time step of the FPGA solver of the Generic Machines in seconds. It is 500ns by default.

Hardware Controller Name (OpCtrl): FPGA controller name that refers to the motor model bitstream (in OpCtrl or Oplnk block). It is usually 'OpCtrl'.

FPGA Clock Period [Tfpga(sec)]: The clock period of the FPGA. It is 5ns by default.

CPU Clock Period [Tcpu(sec)]: The time step of the CPU model. It is 20μs by default.

Communications Settings Automatic Configuration:This will enable the automatic setting of the communications ports. The *.conf file linked to the *.bin file selected in the OpCtrl Controller will be parsed and the communications settings will be set accordingly. If unchecked, the fields become modifiable for manual user settings.

Machine Core: If Communications Settings Automatic Configuration is enabled, Machine Core allows the selection of which machine defined in the *.conf to use for automatic configuration. To know more about how cores are defined inside a *.conf file, see: Conf File Writing Conventions.

Configuration Port Number: Data In/Load In/Data Out port: Number of communication ports from/to FPGA to send/receive solver data. Port numbers depend on the bitstream. See the associated bitstream *.conf file to get the right port numbers. These parameters should be updated at every firmware update.

The description keys to look depend on the selected block mode:

  • For Generic machine mode, the description key used is IM_SM

  • For PMSM Vdq mode, the description key used if PMSMVDQ

Machine TABs

Depending on the number of machines selected in the General tab, corresponding tabs will appear. Each tab has Configuration, Electrical, Mechanical, Resolver, and Encoder Parameters sections:

Configuration

Machine Type: In the dropdown list of each tab, the machine and its rotor type can be selected as Synchronous Machine Round Rotor/Salient-pole Rotor or Doubly-fed Induction Machine or Induction Machine with Squirrel-cage when the Generic machine mode is selected in the general tab. In PMSM mode, the machine parameter can be set as "Fixed Ld Lq values" for PMSM with salency simulation or "BLDC" for brushless dc motor emulation with trapezoidal back emf.

  • Configure Machine Inputs: This button opens a voltage mapping table for each machine as follows:

  • Input Name shows the stator and rotor (if applicable) supply voltage names for the selected machine type and rotor type,

  • Input Source gives the option of selecting between different available eHS sources,

  • Measurement Index is to assign the eHS indexed measurement to the corresponding machine input.

     

    For different types of machine voltage mapping, refer to the info below:

  • For Synchronous Machine, the stator voltages and field rotor voltage should be mapped,

  • For Doubly-fed (Wound Rotor) Induction Machine, the stator voltages and rotor voltages should be mapped,

  • For Induction Machine with Squirrel-cage Rotor, PMSM or BLDC, the stator voltages should be mapped.

Configure eHS inputs: This button opens a current mapping table for each machine as follows:

  • Input Name shows the stator and rotor (if applicable) current names for the selected machine type,

  • Input Source gives the option of selecting between different machine types, either PMSM or generic machine,

  • Measurement Index is to assign the eHS current measurement to the corresponding machine.

Same as Machine Inputs, eHS inputs mapping could be different for each type of machine.

  • For Synchronous Machine, stator currents and field rotor current should be mapped,

  • For Doubly-fed (Wound Rotor) Induction Machine, stator currents and rotor currents should be mapped,

  • For Induction Machine with Squirrel-cage Rotor, stator currents should be mapped.

  • For PMSM or BLDC, stator currents should be mapped. Since the model supports only balanced mode, only 2 currents needs to be injected to the eHS.

For more info about the number of current measurements for each type of machine, refer to the following link: Generic Machine Outputs

For measurement index, eight current measurements channels are assigned for each machine, while up to the first six of them could output current values during real-time simulation.

Refer to the following table for the right signal indexes of the Generic machine outputs to the eHS, SM represents for Synchronous Machine.

Index

Current Sources

Notes

1

Machine #1 Ia Stator Current



2

Machine #1 Ib Stator Current



3

Machine #1 Ic Stator Current



4

Machine #1 Ia Rotor Current

SM #1 Field Rotor Current

5

Machine #1 Ib Rotor Current

Not available for SM #1

6

Machine #1 Ic Rotor Current

Not available for SM #1

7/8

Reserved for internal use



9

Machine #2 Ia Stator Current



10

Machine #2 Ib Stator Current



11

Machine #2 Ic Stator Current



12

Machine #2 Ia Rotor Current

SM #2 Field Rotor Current

13

Machine #2 Ib Rotor Current

Not available for SM #2

14

Machine #2 Ic Rotor Current

Not available for SM #2

15/16

Reserved for internal use



17

Machine #3 Ia Stator Current



18

Machine #3 Ib Stator Current



19

Machine #3 Ic Stator Current



20

Machine #3 Ia Rotor Current

SM #3 Field Rotor Current

21

Machine #3 Ib Rotor Current

Not available for SM #3

22

Machine #3 Ic Rotor Current

Not available for SM #3

23/24

Reserved for internal use



25

Machine #4 Ia Stator Current



26

Machine #4 Ib Stator Current



27

Machine #4 Ic Stator Current



28

Machine #4 Ia Rotor Current

SM #4 Field Rotor Current

29

Machine #4 Ib Rotor Current

Not available for SM #4

30

Machine #4 Ic Rotor Current

Not available for SM #4

31/32

Reserved for internal use



Refer to the following table for the right signal indexes of the PMSM VDQ outputs to the eHS.

Index

Current Sources

Notes

1

Machine #1 Ia Stator Current



2

Machine #1 Ib Stator Current



3

Machine #2 Ia Stator Current



4

Machine #2 Ia Rotor Current



Notes: Ic current is not available for coupling eHS with PMSM VDQ model since the model supports balanced mode only.

Electrical Parameters

Synchronous Machine with Round Rotor: This configuration is used for dynamic modeling of a Round Rotor Synchronous Machine, which models stator, field, and up to three damper windings one on the D-Axis (Kd) and two on the Q-axis (Kq1 and Kq2). All the rotor parameters, including the field and damper windings, are referred to the stator identified by a prime sign. By choosing open-winding option, the model has the option of having neutral point connection for the star-connected stator winding. The mask and electrical parameters of a Round Rotor Synchronous Machine are presented as follows:

Symbol

Name

Description

Unit

Rs

Stator resistance

Per-phase stator winding resistance

Ω

Lls

Stator leakage inductance

Per-phase stator winding leakage inductance

H

Lmd

D-axis magnetizing inductance

Magnetizing inductance in direct-axis direction

H

Lmq

Q-axis magnetizing inductance

Magnetizing inductance in quadrature-axis direction

H

Rfd'

Field resistance

Direct-axis field winding resistance, referred to the stator

Ω

Llfd'

Stator leakage inductance

Direct-axis field winding leakage inductance, referred to the stator

H

Rkd'

D-axis damper resistance

Direct-axis damper winding resistance, referred to the stator

Ω

Llkd'

D-axis damper leakage inductance

Direct-axis damper winding leakage inductance, referred to the stator

H

Rkq1'

1st q-axis damper resistance

1st quadrature-axis damper winding resistance, referred to the stator

Ω

Llkq1'

1st q-axis damper leakage inductance

1st quadrature-axis damper winding leakage inductance, referred to the stator

H

Rkq2'

2nd q-axis damper resistance

2nd quadrature-axis damper winding resistance, referred to the stator

Ω

Llkq2'

2nd q-axis damper leakage inductance

2nd quadrature-axis damper winding leakage inductance, referred to the stator

H

Nsf

Stator to field turn ratio

This turn ratio is used when the voltage ratio between the stator and the field is not unitary

-

R0

Zero-sequence resistance

Zero-sequence stator winding resistance

Ω

L0

Zero-sequence inductance

Zero-sequence stator winding leakage inductance

H

 

Synchronous Machine with Salient-pole Rotor: This configuration is used for dynamic modeling of a Salient-pole Rotor Synchronous Machine, which models stator, field, and up to two damper windings one on the D-Axis (Kd) and one on the Q-axis (Kq1). All the rotor parameters, including the field and damper windings, are reffered to the stator identified by a prime sign. By choosing open-winding option, the model has the option of having neutral point connection for the star-connected stator winding. The mask and electrical parameters of a Salient-pole Rotor Synchronous Machine are presented as follows:

Symbol

Name

Description

Unit

Rs

Stator resistance

Per-phase stator winding resistance

Ω

Lls

Stator leakage inductance

Per-phase stator winding leakage inductance

H

Lmd

D-axis magnetizing inductance

Magnetizing inductance in direct-axis direction

H

Lmq

Q-axis magnetizing inductance

Magnetizing inductance in quadrature-axis direction

H

Rfd'

Field resistance

Direct-axis field winding resistance, referred to the stator

Ω

Llfd'

Stator leakage inductance

Direct-axis field winding leakage inductance, referred to the stator

H

Rkd'

D-axis damper resistance

Direct-axis damper winding resistance, referred to the stator

Ω

Llkd'

D-axis damper leakage inductance

Direct-axis damper winding leakage inductance, referred to the stator

H

Rkq1'

1st q-axis damper resistance

1st quadrature-axis damper winding resistance, referred to the stator

Ω

Llkq1'

1st q-axis damper leakage inductance

1st quadrature-axis damper winding leakage inductance, referred to the stator

H

Nsf

Stator to field turn ratio

This turn ratio is used when the voltage ratio between the stator and the field is not unitary

-

R0

Zero-sequence resistance

Zero-sequence stator winding resistance

Ω

L0

Zero-sequence inductance

Zero-sequence stator winding leakage inductance

H

 

Induction Machine with Squirrel-Cage Rotor: This configuration is used for dynamic modeling of a Squirrel-cage Induction Machine, which models the stator winding and squirrel-cage rotor. All the rotor parameters are reffered to the stator identified by a prime sign. By choosing open-winding option, each stator induction can be access allowing wie with neutral or delta connection on the stator side. The mask and electrical parameters of a Squirrel-Cage Induction Machine are presented as follows:

Symbol

Name

Description

Unit

Rs

Stator resistance

Per-phase stator winding resistance

Ω

Lls

Stator leakage inductance

Per-phase stator winding leakage inductance

H

Rr'

Rotor resistance

Per-phase equivalent rotor winding resistance referred to the stator

Ω

Llr'

Rotor leakage inductance

Per-phase equivalent rotor winding leakage inductance referred to the stator

H

Lm

Mutual inductance

Stator-rotor mutual (magnetizing) inductance

H

R0

Zero-sequence resistance

Zero-sequence stator winding resistance

Ω

L0

Zero-sequence inductance

Zero-sequence stator winding leakage inductance

H

 

Induction Machine with Double Squirrel-cage Rotor: This configuration is used for dynamic modeling of a Double Squirrel-cage Induction Machine, which models the stator winding and two squirrel-cages for the rotor. All the rotor parameters are reffered to the stator identified by a prime sign. The mask and electrical parameters of a Double Squirrel-cage Induction Machine are presented as follows:

Symbol

Name

Description

Unit

Rs

Stator resistance

Per-phase stator winding resistance

Ω

Lls

Stator leakage inductance

Per-phase stator winding leakage inductance

H

Rr1'

Cage 1 rotor resistance

Cage 1 per-phase equivalent rotor winding resistance referred to the stator

Ω

Llr1'

Cage 1 rotor leakage inductance

Cage 1 per-phase equivalent rotor winding leakage inductance referred to the stator

H

Rr2'

Cage 2 rotor resistance

Cage 2 per-phase equivalent rotor winding resistance referred to the stator

Ω

Llr2'

Cage 2 rotor leakage inductance

Cage 2 per-phase equivalent rotor winding leakage inductance referred to the stator

H

Lm

Mutual inductance

Stator-rotor mutual (magnetizing) inductance

H

 

Doubly-fed Induction Machine: This configuration is used for dynamic modeling of a Doubly-fed Induction Machine, which models the stator and rotor windings. All the rotor parameters are reffered to the stator identified by a prime sign. The mask and electrical parameters of a Doubly-fed Induction Machine are presented as follows:

Symbol

Name

Description

Unit

Rs

Stator resistance

Per-phase stator winding resistance

Ω

Lls

Stator leakage inductance

Per-phase stator winding leakage inductance

H

Rr'

Rotor resistance

Per-phase rotor winding resistance referred to the stator

Ω

Llr'

Rotor leakage inductance

Per-phase rotor winding leakage inductance referred to the stator

H

Lm

Mutual inductance

Stator-rotor mutual (magnetizing) inductance

H

Nsr

Stator to rotor turn ratio

Stator to rotor turn ratio

-

Rs0

Zero-sequence resistance (Stator)

Zero-sequence stator winding resistance

Ω

Ls0

Zero-sequence inductance (Stator)

Zero-sequence stator winding leakage inductance

H

Rr'0

Zero-sequence resistance (Rotor)

Zero-sequence rotorwinding resistance

Ω

Lr'0

Zero-sequence inductance (Rotor)

Zero-sequence rotor winding leakage inductance

H

 

PMSM Fix Ld Lq mode: This configuration is used for dynamic modeling of a PMSM with constant parameters. The mask and electrical parameters of the PMSM in Fix DQ mode are presented as follows:

Symbol

Name

Description

Unit

Rs

Stator resistance

Per-phase stator winding resistance

Ω

Ld

Direct-axis inductance

Stator winding phase to neutral inductance on the D-Axis

H

Lq

Quadrature-axis inductance

Stator winding phase to neutral inductance on the Q-Axis

H

FluxPM

Permanent magnet flux linkage

The constant flux per pole pairs induced in the stator windings by the rotor magnets

Wb

DqTheta

Rotor flux position at theta = 0

Offset angle applied to the dq transform to have magnet flux aligned or 90degree behind phase A

Deg

 

BLDC mode: This configuration is used for dynamic modeling of a BLDC with constant parameters. The mask and electrical parameters of the BLDC mode are presented as follows:

Symbol

Name

Description

Unit

Rs

Stator resistance

Per-phase stator winding resistance

Ω

Ls

Stator leakage inductance

Stator winding phase to neutral inductance

H

FluxPM

Permanent magnet flux

The constant flux per pole pairs induced in the stator windings by the rotor magnets

Wb

BEMFFlatArea

Back EMF flat area

Electrical angle width of the flat area of the trapezoidal back EMF

Deg

DqTheta

Rotor flux position at theta = 0

Offset angle applied to the dq transform to have magnet flux aligned or 90degree behind phase A

Deg


Mechanical Parameters

In the mechanical section, the Mechanical Mode drop down list gives the following options

  • Speed, which excludes the mechanical model to run the machine in speed mode. In this mode, Enable Mechanical Port gives the option of setting the speed command as a constant parameter in the mask, or as an extrenal port at the input of the block.

  • Mechanical Torque, which includes the mechanical model to run the machine in torque mode. In this mode, Enable Mechanical Port gives the option of setting the torque command as a constant parameter in the mask, or as an external port at the input of the block. The machines can operate in both motor mode, when the torque (load) is positive, and generating mode, when the torque (input) is negative.

  • External mode, which allows controling the mechanical mode from outside of the block specially when the mechanical mode change during the simulation is required. By selecting this option three ports of Mechanical Mode, Speed, and Torque will appear at the input of the block. Mechanical Mode input constant of 0 or 1 corresponds to the speed or mechanical torque mode, respectively.

Symbol

Name

Description

Unit

pp

Pole Pair

Number of pole pairs

-

J

Rotor Inertia

Rotor moment of inertia

kg.m^2

Fv

Viscous Friction Coefficient

Viscous friction coefficient

N.m.s/rad

Fs

Static Friction Torque

Static friction torque

N.m

W0

Initial Speed

Initial speed

rpm

Be aware the max number of pole pair supported is increased to 127 rather than 31 since eFPGAsim 2.7.

 

Resolver and Encoder Parameters

By checking the Enable Resolver/Encoder, the resolver/encoder parameters appear in the mask. Two encoder mode can be available (Quadrature or Hall effect). Direction of Sensor Rotation determines if it is either clockwise or counter clockwise. For the resolver, the Excitation Source Type determines the source from which the excitation of the resolver is generated. It can either be AC, which is generated inside the FPGA with the specified frequency, DC, which is generated with a 90-degree from the rotor and External, which is generated from outside the model through Analog In Channel assignment. The Resolver Sine and Cosine Gains are in a vector of 4×1.

For Resolver Sine and Cosine Gains [Rk], four parameters are Sin.Sin, Sin.Cos, Cos.Sin and Cos.Cos. The resolver Sine and Cosine outputs are calculated by using the following two equations. To simulate the resolver ideally, set Sin.Sin and Cos.Cos to 1 while Sin.Cos and Cos.Sin to 0.

Symbol

Name

Description

Unit

Rpp

Number of Pole Pairs of the Resolver and Encoder

Number of pole pairs of the resolver and encoder

Note: Only disabled when both Resolver and Encoder are disabled

-

Roffset

Resolver Angle Offset

Angle offset between the resolver and the rotor position from 0 to 360 degrees

deg

Rk

Resolver Sine and Cosine Gains

Vector of 4 sine/cosine modulation output sine/cosine component amplitude between 0 and 1

-

Ef

Excitation Frequency

Frequency of the excitation when the source is in AC mode

Hz

Ets

Excitation Time Shift

This parameter is used to compensate the time offset between the carrier generation's input in the system and modulated signals' output

s

Qppr

Number of pulses per revolution

Number of pulses in one full revolution of the encoder

-

Roffset

Encoder Angle Offset

Angle offset between the encoder and the rotor position from 0 to 360 degrees

deg

Hpos

Hall effect sensor positions

Vector of 3 elements that give in electrical angle the positions of the Hall effect sensors A B C in this order

deg


Inputs

Mechanical Mode:This port allows controling the mechanical mode from outside of the block specially when the mechanical mode change during the simulation is required. Mechanical Mode input constant of 0 or 1 corresponds to the speed or mechanical torque mode, respectively.

Speed: This port is used for the speed command. It is available when the mechanical mode is set to external, or it is set to speed and the Enable Mechanical Port is set to external port.

Torque: This port is used for the load torque command. It is available when the mechanical mode is set to external, or it is set to torque and the Enable Mechanical Port is set to external port.


Outputs

Machine signals (Generic machine mode): For each machine, the following signals are available at the monitoring port:

Signal Name

Description

Vsq

Quadratic stator voltage.

Vsd

Direct stator voltage.

Vrq

Quadratic rotor voltage, seen from stator.
Exception: Seen from rotor field voltage for synchronous machine.

Vrd

Direct rotor voltage, seen from stator.
Exception: Unused for synchronous machine.

Phisq

Quadratic stator flux.

Phisd

Direct stator flux.

Phirq

Quadratic rotor flux, seen from stator.
Exception: Field flux for synchronous machine.

Phird

Direct rotor flux, seen from stator.
Exception: Damper Kd flux for synchronous machine.

Isq

Quadratic stator current.

Isd

Direct stator current.

Irq

Quadratic rotor current, seen from stator.
Exception: Field current for synchronous machine.

Ird

Direct rotor current, seen from stator.
Exception: Damper Kd current for synchronous machine.

isa

First stator phase current.

isb

Second stator phase current.

isc

Third stator phase current.

ira

First rotor phase current, seen from stator.
Exception: Seen from rotor for doubly-fed induction machine.
Exception: Seen from rotor field current for synchronous machine

irb

Second rotor phase current, seen from stator.
Exception: Seen from rotor for doubly-fed induction machine.
Exception: Unused for synchornouc machine

irc

Third rotor phase current, seen from stator.
Exception: Seen from rotor for doubly-fed induction machine.
Exception: Unused for synchornouc machine

Torque

Electrical torque

w

Motor speed in rpm

thetam

Mechanical rotor angle in degrees

Resolver sin

sin waveform from the resolver

Resolver cos

cos waveform from the resolver

Resolver carrier

carrier waveform from the resolver


Machine signals (PMSM mode): For each machine, the following signals are available at the monitoring port:

Signal Name

Description

Ia

First stator phase current.

Ib

Second stator phase current.

Ic

Third stator phase current.

VaFiltered

First stator phase voltage filtered.

VbFiltered

Second stator phase voltage filtered.

VcFiltered

Third stator phase voltage filtered.

ActivePower

Instantaneous active power.

ReactivePower

Instantaneous reactive power.

Id

D-axis current.

Iq

Q-axis current.

ThetaMec

Mechanical rotor angle in degrees.

ThetaElec

Electrical rotor angle in degrees.

ElectomagneticTorque

Electrical torque in Nm.

SineResolver

sin waveform from the resolver.

CosineResolver

cos waveform from the resolver.

ExcitationResolver

carrier waveform from the resolver.

ThetaResolver

Resolver angle in degrees use for Sine Cosine modulation.

SpeedRPM

Electrical machine speed in Revolution per minutes.

TotalTorque

Torque resultant after static friction (electromagnetic torque - torque load - static friction).

BackEmfA

Back Emf voltage of phase A in Volts.

BackEmfB

Back Emf voltage of phase B in Volts.

BackEmfC

Back Emf voltage of phase C in Volts.


Characteristics and limitations

Offline simulation: This block is not capable of offline simulation.

Communication delays: The block latency is 2 CPU Time steps.

Direct Feedthrough

NO

Discrete sample time

YES

XHP support

YES

Work offline

NO




If you require more information, please contact https://www.opal-rt.com/contact-technical-support/.

OPAL-RT TECHNOLOGIES, Inc. | 1751, rue Richardson, bureau 1060 | Montréal, Québec Canada H3K 1G6 | opal-rt.com | +1 514-935-2323