Documentation Home Page ◇ RT-LAB Home Page
Pour la documentation en FRANÇAIS, utilisez l'outil de traduction de votre navigateur Chrome, Edge ou Safari. Voir un exemple.
Common Mezzanine Option
Block
OP5369 bidirectional 32 digital inputs/outputs card block
OP5330 16 analog outputs card block
OP5367-3 bidirectional 16 digital inputs/16 digital outputs card block
OP5367-5 32 digital inputs card block
OP48H10 - Fast
Mask
OP5369 available configuration parameters
OP5330 available configuration parameters
OP5367-3 available configuration parameters
OP5367-5 available configuration parameters
OP48H10 - Fast available configuration parameters
Description
The mezzanine option block is used to configure the parameters of a mezzanine during the load of the simulation.
Parameters
Controller name | Bind this block to an OpCtrl or an OpLnk block by entering the same 'Controller Name' as specified in one of these blocks. |
---|---|
Mezzanine type | A drop-down list of the cards supported by this block |
Chassis slot | A drop-down list of the physical location of the mezzanine to be configured |
Enable 2Msps / 8 Channels mode | Checking this box sets the analog out to 2Msps maximum sampling rate; if unchecked it is set to 1Msps maximum sampling rate. This parameter is only available for the OP5330 mezzanine type. |
Threshold low | The voltage level of the falling edge detection value to be configured. The resolution is 0.1176 V for OP5369 and 0.2022 V for OP5367-3 and OP5367-5. |
Threshold high | The voltage level of the rising edge detection value to be configured. The resolution is 0.1176 V for OP5369 and 0.2022 V for OP5367-3 and OP5367-5. |
Mezzanine type
The following table describes the supported Mezzanine type.
Mezzanine type | Description |
---|---|
OP5369 - 32DIO | With an OP5369 digital bidirectional card, the detection voltages for a rising edge (threshold high) and a falling edge (threshold low) are configurable during a load of an RT-LAB model. The values for the low and high thresholds are applicable for entire groups of 8 channels. Threshold units are volts, and the resolution is 0.1176 V. |
OP5330 - 16 AO | With an OP5330 AO card, the maximum sampling rate for analog out is configurable during load of an RT-LAB model. The supported maximum sampling rates are 1Msps and 2Msps. In the case of 2Msps, the available channels are channel 0, 1, 4, 5 for the first subsection and channel 8, 9, 12, 13 for the second subsection. |
OP5367-3 - 16DI/16DO | With an OP5367-3 digital bidirectional card, the detection voltages for a rising edge (threshold high) and a falling edge (threshold low) are configurable for the first 16 channels during a load of an RT-LAB model. The values for the low and high thresholds are applicable for entire groups of 8 channels. Threshold units are volts, and the resolution is 0.2022 V. |
OP5367-5 - 16DI | With an OP5367-5 digital input card, the detection voltages for a rising edge (threshold high) and a falling edge (threshold low) are configurable for the 32 channels during a load of an RT-LAB model. The values for the low and high thresholds are applicable for entire groups of 8 channels. Threshold units are volts, and the resolution is 0.2022 V. |
OP48H10 - Fast | With an OP48H10 - Fast type, the directions of the bidirectional digitals are configurable for every group of 8 channels. If an output is selected as direction, the voltage output can be configured to either 3.3V or 5V. The supported maximum sampling rate for analog inputs is 5Msps. The supported maximum sampling rate for analog outputs is 10Msps. |
Inputs
This block has no input.
Outputs
Status: This output returns the following values:
Value | Description |
---|---|
0 | No error. |
-1 | An error occurred during the mezzanine configuration. Please refer to the RT-LAB log for more information. |
Characteristics and Limitations
- The mezzanine option blocks can be linked to an OpCtrl block or to an OpLnk block. However, all the mezzanine option blocks related to the same FPGA must be in the same RT-LAB subsystem.
- The feature OP5369 is supported with bitstreams generated with RT-XSG version 3.3.1 and above.
- The feature OP5330 is supported with bitstreams generated with RT-XSG version 3.3.2 and above.
- The features OP5367-3 and OP5367-5 are supported with bitstreams generated with RT-XSG version 3.3.3 and above.
- The feature OP48H10 - Fast is supported with bitstreams generated with RT-XSG version 3.5.0 and above.
OPAL-RT TECHNOLOGIES, Inc. | 1751, rue Richardson, bureau 1060 | Montréal, Québec Canada H3K 1G6 | opal-rt.com | +1 514-935-2323