Description
The Analog Out block is used to transfer analog output voltage values to be applied to the analog output channels of an OP533X module installed different type of carrier compatible with the selected FPGA board.
The data values are transferred to the FPGA from the RT-LAB model through one DataIn port of the bitstream, via the PCIe bus of the target computer.
Each bitstream using Analog Output channels comes with a configuration file that lists the Data port number and the corresponding OP533X modules location in the system. The configuration file name is the same as the bitstream file name entered in the OpCtrl block, with the extension .conf instead of .bin. This configuration file uses different parameters to describe the location of the OP533X channels, depending on the FPGA associated with the controller they are attached to:
Board | Configuration |
---|---|
OP48xx | The slot number ranges from 1 to 2. Each slot has an OP48H10 card (fast type) which contains three modules (A, B and C). The module A corresponds to the digital I/Os and modules B and C correspond to analog output and analog input respectively. The subsection (1, 2, 3 or 4), is a subset of channels for the card in question. In analogs, subsection '1' returns values for the 8 first channels of the OP48H10, and subsection '2' returns values for the 8 last channels. In digitals, there are 4 subsections, where each subsection represents 8 channels. |
OP5142 | The slot number ranges from 1 to 4. Each slot has two modules (i.e. two cards). |
The module (A or B) is the location of the OP533X card on the carrier. Module 'A' refers to the card at the front of the simulator and module 'B' refers to the card at the back of the simulator for the slot in question. | |
The subsection (1 or 2), is a subset of channels for the card in question. Subsection '1' returns values for the 8 first channels of the OP533X, and subsection '2' returns values for the 8 last channels. | |
ML605 | The slot number ranges from 1 to 4. Each slot has two modules (i.e. two cards). |
The module (A or B) is the location of the OP533X card on the carrier. Module 'A' refers to the card at the front of the simulator and module 'B' refers to the card at the back of the simulator for the slot in question. | |
The subsection (1 or 2), is a subset of channels for the card in question. Subsection '1' returns values for the 8 first channels of the OP533X, and subsection '2' returns values for the 8 last channels. | |
OP7160/OP7161 | The slot number ranges from 1 to 16. Each slot has one module (one card). |
The module (A or B) is obsolete for OP7000 I/O box. | |
The subsection (1 or 2), is a subset of channels for the card in question. Subsection '1' returns values for the 8 first channels of the OP533X, and subsection '2' returns values for the 8 last channels. | |
VC707 | The slot number ranges from 1 to 4. Each slot has two modules (i.e. two cards). |
The module (A or B) is the location of the OP533X card on the carrier. Module 'A' refers to the card at the front of the simulator and module 'B' refers to the card at the back of the simulator for the slot in question. | |
The subsection (1 or 2), is a subset of channels for the card in question. Subsection '1' returns values for the 8 first channels of the OP533X, and subsection '2' returns values for the 8 last channels. | |
OP4500 / TE0741 | The slot number ranges from 1 to 2. Each slot has two modules (i.e. two cards). |
The module (A or B) is the location of the OP533X card on the carrier. Seen from the back of the simulator, the module 'A' is the leftmost card on the corresponding group and module 'B' is the right-most card. | |
The subsection (1 or 2), is a subset of channels for the card in question. Subsection '1' returns values for the 8 first channels of the OP533X, and subsection '2' returns values for the 8 last channels. |
The user must refer to the configuration file (opened with any text editor) for selecting the DataIn port number for the desired Analog Output channels. The Analog Out block then parses the configuration file and displays the Slot, Section and Sub-section values corresponding to the DataIn port number in the 'Slot infos' parameter.
The maximum number of Analog Output channels controlled by one Analog Out is limited by the size of the subset of channels in one sub-section, usually 8.
Parameters
ControllerName | Bind this block to an OpCtrl block by entering the same 'Controller Name' as specified in the OpCtrl block. The OpCtrl block controls initialization of the settings of one specific FPGA card in the system. |
---|---|
DataIn port number | Enter the number of the DataIn port to be controlled by this block, in the range [1:64] for the VC707, TE0741 and OP48xx FPGAs and [1:32] for all others. |
Slot infos | This non-editable parameter displays the physical location of the analog output channels related to the selected DataIn port, as obtained from the parsing of the configuration file. |
Maximum number of AOut channels controlled by this block | This non-editable parameter displays the number of channels in one sub-section listed in the configuration file. |
Number of AOut channels | Enter the number of channels for which data values will be transmitted at each calculation step. This number must be less than or equal to the value of the 'Maximum number of AOut channels' parameter. The data transfer mechanism between RT-LAB and the FPGA card does not allow the selection of individual channels in the sub-section of channels. The data supplied by the block will thus apply to the N first channels of the sub-section, where N is the value of the 'Number of AOut channels' parameter. |
Set Voltage Range from input port | When this option is checked an additional input labeled Voltage Range appears on the block. Three (3) choices are available: +/- 16 V, +/-10 V, +/- 5 V. A constant value should be connected to the input in order to select the Voltage Range, as indicated in the table below. Note: This option is not available when the selected board type in OpCtrl is OP48xx. |
Voltage range | Enter the voltage range that should be used by the Analog Out block. Three (3) choices are available : +/- 16 V, +/-10 V, +/- 5 V. Note: This option is disabled when the board type selected in OpCtrl is OP48xx. The following voltage range is selected by default: +/-10 V. |
Constant Value | Voltage Range Selected |
---|---|
5 | +/- 5 V |
10 | +/-10 V |
Any other number | +/- 16 V |
Note:
- Voltage Range must be the same for all channels. When having two Analog Out blocks driving the same mezzanine (Subsections A and B), both of them must have the same Voltage Range selection. Same constant value should be applied to both of them.
- The 16-bit resolution for the D/A is maintained when you select any of the three voltage range available.
- Once this option is checked and the Apply button is hit, the Voltage Range option below disappears.
Inputs
Volts: This input supplies the voltage values, in Volts, for the subset of channels selected. The voltage range of the OP5330 module is specified by the 'Voltage Range' parameter. Out of range values get saturated before being submitted to the card.
Outputs
Status: This output returns the following values:
Value | Description |
---|---|
0 | No error. |
-1 | Block could not be matched with an OpCtrl block (check the 'controller Name' value), or FPGA card initialization problem. |
-2 | Internal memory initialization problem. |
-7 | Data values out of range. The OP5330 module output range is specified by the 'Voltage Range' parameter. Out of range values get saturated to these levels. |
Characteristics and Limitations
Connector Pin Assignments
The user should refer to the carrier documentation for connector pin assignments.