Selectable Digital Input
Description
This block implements an 8-channel digital input subsection as either Static digital intput, EventDetector input or Pulse-Width Modulated input.
Mask
Inputs
LoadInSel: This port should be connected to the LoadIn port carrying the Digital Input type selection.
HSIn: This port should be connected to the 8-bit signal corresponding to one IO-Group subsection.
Outputs
DataOut: This port should be connected to a DataOut port.
DataSync: This port should be connected to a DataSync port, with the same index as the port connected to the DataOut output of this block.
Characteristics and limitations
This block has no special characteristics.
Direct Feedthrough | YES |
Discrete sample time | NO |
XHP support | N/A |
Work offline | YES |