Route Mechanical Signals block
Description
The Route Mechanical Signals block is used to route the mechanical angles coming from the different machines to the resolvers / encoders modules available within the firmware. It can process up to 10 angles.
Mask
Inputs
LoadIn: This input is to configure the angle routing prior to the Real-Time Simulation. It has to be connected to a LoadIn port in asynchronous mode.
loadInSof: This port must be connected to the associated Start of Frame of the previous LoadIn.
Theta0-9: The angles represents the mechanical theta angles, in turn ratio, in UFix24_24 format, coming from the different machines.
Outputs
Out1,2: The Route Mechanical Signals outputs angles which are used as inputs for the first Resolver Encoder.
Out3,4: The Route Mechanical Signals outputs angles which are used as inputs for the second Resolver Encoder.
Characteristics and limitations
This block has no special characteristics.
Direct Feedthrough | N/A |
Discrete sample time | N/A |
XHP support | N/A |
Work offline | NO |
If you require more information, please contact https://www.opal-rt.com/contact-technical-support/.