Documentation Home Page eHS Toolbox Home Page
Pour la documentation en FRANÇAIS, utilisez l'outil de traduction de votre navigateur Chrome, Edge ou Safari. Voir un exemple.

Route Mechanical Signals block - efs_xsgRouteMechanicalSignals

Block


Table of Contents

Description

The Route Mechanical Signals block is used to route the mechanical angles coming from the different machines to the resolvers / encoders modules available within the firmware. It can process up to 10 angles.


Mask


Inputs

LoadIn: This input is to configure the angle routing prior to the Real-Time Simulation. It has to be connected to a LoadIn port in asynchronous mode.

loadInSof: This port must be connected to the associated Start of Frame of the previous LoadIn.

Theta0-9: The angles represents the mechanical theta angles, in turn ratio, in UFix24_24 format, coming from the different machines.


Outputs

Out1,2: The Route Mechanical Signals outputs angles which are used as inputs for the first Resolver Encoder.

Out3,4: The Route Mechanical Signals outputs angles which are used as inputs for the second Resolver Encoder.


Characteristics and limitations

This block has no special characteristics.

Direct FeedthroughN/A
Discrete sample timeN/A
XHP supportN/A
Work offlineNO


If you require more information, please contact https://www.opal-rt.com/contact-technical-support/.

OPAL-RT TECHNOLOGIES, Inc. | 1751, rue Richardson, bureau 1060 | Montréal, Québec Canada H3K 1G6 | opal-rt.com | +1 514-935-2323
Follow OPAL-RT: LinkedIn | Facebook | YouTube | X/Twitter