Documentation Home Page ◇ eHS Toolbox Home Page
Pour la documentation en FRANÇAIS, utilisez l'outil de traduction de votre navigateur Chrome, Edge ou Safari. Voir un exemple.
eHS to Machines Mapping Interface - efs_xsgEhsMachineMapping
Description
This block provides a standard eHS to Machines Mapping Interface. It allows the user to route signals from the eHS outputs to any of the machine models connected using a user-defined configuration.
Mask
Inputs
LoadIn: This input should be connected to a LoadIn port. It receives the user-defined configuration from the RT-LAB model.
LoadInSof: This input should be connected to a LoadIn SOF port. Port number must be the same as LoadIn one.
From eHS: This input carries the signals coming from eHS ( Data Signal, Valid Signal, Last signal and Reset).
Outputs
Sync: This output is active high. When active, it triggers the writting of outputs using user-defined configuration.
EhsRst: This output is used as a active high global reset for the functionality. When used, user-configuration needs to be sent again, and data is equal to 0.
DualMotorVDQ_0: This output provides the data needed for the mux containing the three-phase voltage (Vabc) of the first PMSM.
DualMotorVDQ_1: This output provides the data needed for the mux containing the three-phase voltage (Vabc) of the second PMSM.
DualMotorVDQ_2: This output provides the data needed for the mux containing the three-phase voltage (Vabc) of the third PMSM.
DualMotorVDQ_3: This output provides the data needed for the mux containing the three-phase voltage (Vabc) of the fourth PMSM.
MotorIM_0: This output provides the data needed for the rotor and stator voltage of the first induction Machine.
MotorIM_1: This output provides the data needed for the rotor and stator voltage of the second induction Machine.
MotorIM_2: This output provides the data needed for the rotor and stator voltage of the third induction Machine.
MotorIM_3: This output provides the data needed for the rotor and stator voltage of the fourth induction Machine.
MotorSRM_0: This output provides the data needed for the five-phased (Vabcde) voltage of the first Switched Reluctance Machine.
MotorSRM_1: This output provides the data needed for the five-phased (Vabcde) voltage of the second Switched Reluctance Machine.
If you require more information, please contact https://www.opal-rt.com/contact-technical-support/.
OPAL-RT TECHNOLOGIES, Inc. | 1751, rue Richardson, bureau 1060 | Montréal, Québec Canada H3K 1G6 | opal-rt.com | +1 514-935-2323
Follow OPAL-RT: LinkedIn | Facebook | YouTube | X/Twitter