Documentation Home Page RT-XSG Toolbox Home Page
Pour la documentation en FRANÇAIS, utilisez l'outil de traduction de votre navigateur Chrome, Edge ou Safari. Voir un exemple.

Inverse Clarke Transform

Block

Block

Mask

Mask

Description

This block performs the inverse of the Clarke transformation of an electrical three-phases system.

All the calculations performed by this block are made on the per-unit scale. Therefore, the user should ensure that inputs are correctly scaled before entering the block.

Parameters

These parameters have been optimized to provide an accuracy better than 0.01% for an angle resolution of 16 bits and has been disabled. If a better resolution is needed, the expert developer can change the parameters by disabling the link between this block and the library.

Output number of bitsSets the number of bits used to format the outputs.
Output binary pointSets the outputs' binary point location.

Inputs

xα ,xβ ,x0These inputs are signals (currents, voltages, etc...) expressed in the Clarke two phases reference frame in the per-unit scale. "x0" corresponds to the homopolar quantity and is equal to zero for balanced systems (xa + xb + xc = 0). Their format is Fix18_16.

Outputs

xa ,xb ,xcThese outputs are per unit signals (currents, voltages etc...) expressed in the three phases reference frame. Their default format is Fix18_16 but can be specified by the user through the mask parameters.

Characteristics and Limitations

This block cannot be used in Virtex5-based platforms, such as the ML50x series.

Direct FeedthroughN/A
Discrete sample timeN/A
XHP supportYES
Work offlineYES

OPAL-RT TECHNOLOGIES, Inc. | 1751, rue Richardson, bureau 1060 | Montréal, Québec Canada H3K 1G6 | opal-rt.com | +1 514-935-2323