Concordia Transform
Block
Mask
Description
This block performs the Concordia transformation of an electrical three-phases system.
All the calculations performed by this block are made in the per-unit scale. Therefore, the user should ensure that inputs are correctly scaled before entering the block.
It is based on the following equations:
Parameters
These parameters have been optimized to provide an accuracy better than 0.01% for an angle resolution of 16 bits, and has been disabled. If a better resolution is needed, the expert developer can change the parameters by disabling the link between this block and the library.
Output number of bits | Sets the number of bits used to format the outputs. |
---|---|
Output binary point | Sets the outputs binary point location. |
Inputs
xa, xb, xc | These inputs are signals (currents, voltages etc...) expressed in the three-phase reference frame in the per unit scale. Their format is Fix18_16. |
---|
Outputs
xα, xβ, x0 | These outputs are per unit signals (currents, voltages etc...) expressed in the Concordia two phases reference frame. "x0" corresponds to the homopolar quantity and is equal to zero for balanced systems (xa + xb + xc = 0). Their default format is Fix18_16 but can be specified by user through the mask parameters. |
---|
Characteristics and Limitations
This block cannot be used in Virtex5-based platforms, such as the ML50x series.
Direct Feedthrough | N/A |
---|---|
Discrete sample time | N/A |
XHP support | YES |
Work offline | YES |