Simulation State
Block
Mask
Description
This block outputs the state of the RT-LAB simulation, sensitive to the 'Load', 'Execute' or 'Pause' buttons from the software tool such RT-LAB. This block can be used to output default values to digital or analog outputs when the simulation is not running.
Parameters
This block has no parameters.
Inputs
This block has no input.
Outputs
Stopped | It is set to '1' when the RT-LAB simulation synchronization signal timed out, the simulation appears to be in reset mode (if the Sync pulse is not received after a delay longer than the timeout time). It goes to '0' while the simulation is running. |
---|---|
Pause | It is set to '1' when simulation = PAUSE. |
Execute | It is set to '1' when simulation = EXECUTE. |
Reset | It is set to '1' when simulation = RESET. |
Load | It is set to '1' when simulation = LOAD. |
Crashed | It is set to '1' when the RT-LAB simulation crashed (lacking Sync and/or Update Request pulse for a period exceeding a timeout time). |
Characteristics and Limitations
This block is only compatible with simulation time steps shorter than 40 milliseconds.