Selectable Digital Input Block

Documentation Home Page RT-XSG Toolbox Home Page
Pour la documentation en FRANÇAIS, utilisez l'outil de traduction de votre navigateur Chrome, Edge ou Safari. Voir un exemple.

Selectable Digital Input Block

Block

Block
Block

Mask

Mask
Mask

Description

This block implements an 8-channel digital input subsection as either Static digital input, EventDetector input or Pulse-Width Measurement input.

Parameters

This block has no parameter.

Inputs

HSIn

This port should be connected to the 8-bit signal corresponding to one IO-Group subsection.

Outputs

DataOut

This port should be connected to a DataOut port.

DataSync

This port should be connected to a DataSync port, with the same index as the port connected to the DataOut output of this block.

Characteristics

This block has no special characteristics.

Direct Feedthrough

YES

Discrete sample time

NO

XHP support

N/A

Work offline

YES

OPAL-RT TECHNOLOGIES, Inc. | 1751, rue Richardson, bureau 1060 | Montréal, Québec Canada H3K 1G6 | opal-rt.com | +1 514-935-2323