OpTrisin

Documentation Home Page RT-XSG Toolbox Home Page
Pour la documentation en FRANÇAIS, utilisez l'outil de traduction de votre navigateur Chrome, Edge ou Safari. Voir un exemple.

OpTrisin

Block

Block
Block

Mask

Mask
Mask

Description

This block is used to generate a three-phase sine wave into an FPGA model. The angle of the leading wave is set by an input to the block, while its amplitude is set by a block parameter.

Parameters

Maximum amplitude

Peak amplitude of the sine waves. The dynamic range of the wave is thus [-Maximum amplitude, +Maximum amplitude]

Post right shift

Used to pre-process the output waves to shift right the bits with the indicated integer number of positions. This is equivalent to multiplying the data by 2^(-Post right shift).

ABC sequence

Used to determine the order of the three phases (A=>B=>C or C=>B=>A).

Inputs

Theta

The angle of the leading sine wave, in radiants. The recommended format is Ufix10_6.

Offset

The offset of the leading sine wave. The format should be Fix10_0, and, when normalized, represents the proportion of a turn of the offset.

Outputs

A, B and C

These three outputs are the three phases of the generator.

Characteristics and Limitations

This block has no special characteristics.

Direct Feedthrough

NO

Discrete sample time

NO

XHP support

N/A

Work offline

YES