Documentation Home Page RT-XSG Toolbox Home Page
Pour la documentation en FRANÇAIS, utilisez l'outil de traduction de votre navigateur Chrome, Edge ou Safari. Voir un exemple.

EnDat 2.2 Master Packing

Block

Mask

Description

This block recovers the data from an EnDat Master Interface block and generates the signals needed by the DataOut block.

Parameters

This block has no parameters.

Inputs

Position ValuePosition Value received from the EnDat Master block.
Additional Data1Additional Data 1 received from the EnDat Master block.
Additional Data2Additional Data 2 received from the EnDat Master block.
ValidOutput Status from the EnDat Master.
CRC ErrorCRC Status bits from the EnDat Master block.
Error 1Error bit 1 of EnDat protocol (Alarm1).
Error 2Error bit 2 of EnDat protocol (Alarm2).

Outputs

DataOut

This port supplies a valid bit and the serialized data of the status/result data received from the EnDat Master block. It is meant to interface the DataOut block to one of its Data_OUTi port.
DataSyncThis port supplies a pulse to indicate the update of the DataOut port. It is to be connected to the DataSynci input port of the DataOut block, with the same i chosen for DataOut port.

Characteristics and Limitations

This block has no specific characteristics or limitations.

OPAL-RT TECHNOLOGIES, Inc. | 1751, rue Richardson, bureau 1060 | Montréal, Québec Canada H3K 1G6 | opal-rt.com | +1 514-935-2323