Documentation Home Page RT-XSG Toolbox Home Page
Pour la documentation en FRANÇAIS, utilisez l'outil de traduction de votre navigateur Chrome, Edge ou Safari. Voir un exemple.

PWMIn Packing

Block

Mask

Description

This block recovers the data from a digital out Interface block and generates the signals needed by the DataOut block.

Parameters

This block has no parameters.

Inputs

SyncThis signal is the synchronization pulse train. It is usually connected to the ModelSync signal.
TimeOn[X] where X=[0,7]This signal corresponds to the total ‘on’ time, in clock ticks, of the last PWM period. It is 20-bit wide.
Period[X] where X=[0,7]This signal represents the total duration value, in clock ticks, of the last PWM period. It is 20-bit wide.

Outputs

DataOut
This signal contains the data of an PWM subsection and a valid bit. It is meant to interface the DataOut block.
DataSyncThis signal represents a pulse to indicate the update of the DataOut port. It is to be connected to the DataSynci input port of the DataOut block corresponding to the channel selected for the DataOut signal.

Characteristics and Limitations

This Block has no specific characteristics or limitations.