Documentation Home Page ◇ HYPERSIM Home Page
Pour la documentation en FRANÇAIS, utilisez l'outil de traduction de votre navigateur Chrome, Edge ou Safari. Voir un exemple.
Components by Library
The HYPERSIM components are all available in the tool palette on the right side of the main window.
- Component Parameter Form Introduction
- Component Sensor Form Introduction
- Control Components
- Control Exciters
- Control Governors
- Control Logic Operations
- Control Math Operations
- Control Measurements
- Control Miscellaneous
- Control Nonlinear and Delay
- Control Protection Relays
- 21 - MHO Distance Relay
- 25 - Synchronism-Check Relay
- 27 - Undervoltage Relay
- 27 - Undervoltage Relay (1-ph)
- 40Q - Loss-of-Excitation Relay
- 49M - Thermal Overload Protection for Motors
- 50-51 - Overcurrent Relay
- 50 - Instantaneous or Definite Time Overcurrent Relay (1-ph)
- 50BF - Breaker Failure Protection
- 51- Inverse Time Overcurrent (1-ph)
- 59 - Overvoltage Relay
- 59 - Overvoltage Relay (1-ph)
- 67 - Directional Overcurrent Relay
- 67 - Directional Relay Based on Impedance
- 79 - Auto recloser
- 81 -Frequency Relay
- 87T - Transformer Differential Relay
- Control Sources
- Constant, Float
- Constant, Integer
- Pulse Train Generator
- PWM Average Generator for 2-Level Converter (Switching Function)
- PWM Average Generator for 3-Level Converter (Switching Function)
- PWM Average Generator for Full-Bridge Converter (Switching Function)
- PWM Generator for 2-Level Converter (Switching Devices)
- PWM Generator for 3-Level Converter (Switching Devices)
- PWM Generator for Full-Bridge Converter (Switching Devices)
- Random Number Generator
- Sine Wave Generator
- Sine Wave Generator With Angle
- Square Wave Generator
- Time Step
- Triangle Wave Generator
- Control Stabilizers
- Control Interfaces
- Control Microgrid
- Control Smart Inverters
- Network Components
- Network Energy Storage
- Network FACTS and HVDC
- Network Filters
- Network Lines and Cables
- Typical Electrical Parameters
- Cable Data
- Constant Param, 1-ph
- Constant Param, 2-ph
- Constant Param, 3-ph
- Constant Param, 3-ph with Fault
- Constant Param, 4-ph
- Constant Param, 6-ph
- Constant Param, 6-ph with Fault
- Constant Param, 9-ph
- Constant Param, 12-ph
- Frequency Dependent, 2-ph
- Frequency Dependent, 3-ph
- Frequency Dependent, 3-ph (SL)
- Frequency Dependent, 4-ph
- Frequency Dependent, 6-ph
- Line Data
- PI Section, 1-ph
- PI Section, 2-ph
- PI Section, 3-ph
- PI Section, 3-ph with Fault
- PI Section, 6-ph
- PI Section, 6-ph with Fault
- PI Section, 9-ph
- PI Section, 12-ph
- PI Section, 12-ph with Fault
- Wideband Line/Cable
- Wideband Line/Cable Fitter
- [Old Source Pages Lines]
- Network Loads
- Network Machines and Generators
- Asynchronous Machine
- Combined Heat and Power (CHP) [New]
- Direct Current Machine
- Double Phase Asynchronous Machine
- Induction Machine (Squirrel Cage) - Legacy
- Induction Machine (Wound Rotor)
- Permanent Magnet Synchronous Machine (PMSM)
- Synch. Machine (Cross-Compound)
- Synch. Machine (dq0-hydraulic)
- Synch. Machine (Hydraulic)
- Synch. Machine (Thermal)
- Synch. Machine with Fault
- Synchronous Machine (pu Fundamental)
- Synchronous Machine (pu Standard)
- [Old Source Pages Machines]
- Network Measurements
- Network Renewable Energy
- Network RLC
- Network Tools
- Network Transformers
- 2-Winding 3-Phase Saturable Autotransformer with Internal Tertiary 3-Limb
- 2-Winding 3-Phase Saturable Autotransformer with Internal Tertiary
- Phase-Shifting Zigzag Transformer
- 4-Winding 1-Phase Linear Transformer with Tap Changer
- 4-Winding 1-Phase Saturable Transformer
- 4-Winding 1-Phase Linear Transformer
- 3-Winding 3-Phase Saturable Transformer with Tap Changer and Decoupling Element
- 3-Winding 3-Phase Saturable Transformer with Tap Changer
- 3-Winding 3-Phase Saturable Transformer
- 3-Winding 3-Phase Saturable Transformer with Internal Tertiary
- 3-Winding 3-Phase Linear Transformer with Internal Tertiary
- 3-Winding 1-Phase Linear Transformer with Tap Changer
- 3-Winding 1-Phase Saturable Transformer
- 3-Winding 1-Phase Linear Transformer
- 3-Winding Impedance-Matrix-Based Transformer with Internal Fault
- 3-Winding Impedance-Matrix-Based Transformer
- 3-Winding 3-Phase Linear Transformer
- 2-Winding 3-Phase Saturable Transformer with Tap Changer
- 2-Winding 3-Phase Saturable Transformer
- 2-Winding 3-Phase Series/Series Linear Transformer
- 2-Winding 3-Phase Series Saturable Transformer
- 2-Winding 3-Phase Series Linear Transformer
- 2-Winding 1-Phase Linear Transformer with Tap Changer
- 2-Winding 1-Phase Saturable Transformer
- 2-Winding 1-Phase Ideal Transformer
- 2-Winding 1-Phase Linear Transformer
- 2-Winding Impedance-Matrix-Based Transformer
- 2-Winding Impedance-Matrix-Based Transformer with Internal Fault
- 2-Winding 3-Phase Linear Transformer
- Network Sources
- Network Switches and Breakers
- Network Voltage Source Converters
- 2-Level Converter (Average)
- 2-Level Converter (Switching Devices)
- 2-Level Converter (Switching Function)
- 3-Level NPC Converter (Switching Devices)
- 3-Level NPC Converter (Switching Function)
- Boost Converter (Switching Function)
- Full-Bridge Converter (Switching Devices)
- Full-Bridge Converter (Switching Function)
- MMC Valve (HB Cells, Avg)
- MMC Valve (HB Cells)
- MMC Valve (FB Cells)
- Signal Routing
- Target Inputs and Outputs
OPAL-RT TECHNOLOGIES, Inc. | 1751, rue Richardson, bureau 1060 | Montréal, Québec Canada H3K 1G6 | opal-rt.com | +1 514-935-2323
Follow OPAL-RT: LinkedIn | Facebook | YouTube | X/Twitter